Acoustics and Low Frequency Damping pt. 3
Now we dive a little deeper into the math involved with controlling small room low frequency behavior. You’ll notice it is relatively simple when compared to some 3-dimensional Sabine/Fitzroy equations. You may also notice that controlling room decay in the bass range is all about dissipating greater and greater portions of the wave energy with each cycle of the wave. Soon you’ll see how easy it is to apply this to your room.
From the AES paper titled as above, by ASC Owner & President, Art Noxon, comes the first of many excerpts from this enlightening piece. Enjoy!
View the entire paper.
Resonant Bandwidth Relations
The “Q” of the resonant mode is linear with frequency for a constant RT60. By referring to the half power bandwidth relationship, the bandwidth is definable in terms of RT60. For a constant RT60 the bandwidth is constant.
The frequency response of a listening room can be taken with a linear frequency sweep. This will show the fixed bandwidth resonances to have the same shape regardless of center frequency.
If it is determined that the ”Q” of some mode needs to be reduced, the proper resistance needs to be added. The energy relations for “Q” yield the required (ΔQ) addition based on initial Qi and final Qf values.
Example:
The bandwidth of the 100 Hz room resonance mode may be found to be 3 Hz giving an initial Qi of 33. The desirable bandwidth might be 5 Hz for a “Q” of 20. The correction required has a strength of 50. It is developed by adding the proper amount of absorption to the resonant mode.
The initial RT60 of the room is .73 seconds. The additional absorption added is sufficient to establish alone in the room an RT60 of 1.1 seconds. The result of the total absorption produces an RT60 of .44 seconds.
In order to provide the correction (ΔQ), a fraction of total energy (F) must be removed from the resonant mode each cycle. The Sabine type equations do not apply here. They are based on absorptive surfaces exposed to diffuse sound fields and are valid above 300 Hz. Here is low frequency absorption and it is related to the volume and position of the absorption relative to that of the standing wave.
Resonant Decay by Discrete Absorption
A basic view of energy absorption allows a fraction (F) of the energy remaining in a system to be removed at a regular rate (1/N times a second). This leads to the exponential decay relations whose “RT60” expression is well known. If the fraction is less than 20%, the system is “lightly damped,” and the log term can be simplified in approximation.
The decay equation is very general. It remains only to define the rate and fraction of energy absorption for any particular system and the RT60 can be predicted.
One Dimension Resonance Decay
The “Impedance Tube” provides a device in which standing waves can be generated and then their decay monitored. The absorption device is located at one end of a tube while the sound source is at the other.

Work is done at the absorption each time there is excess pressure. This occurs twice each cycle, once when the pressure goes positive, and then again when it goes negative. The rate of absorption is twice the resonant frequency.
The fraction of energy lost by each absorption depends on the position and number of traps in the resonant field. A trap located at one end of the impedance tube (A) experiences pressure pulses and can absorb energy. The same trap located at a pressure node (B) experiences no pressure change and does no work.
With that, you’ve seen how to quickly manipulate the bass range RT60 of a small room through the addition of damping. You’ve also briefly seen where one might position a damping device to glean the maximum benefit. Next newsletter, you will see the relationship between using these important positions to increase the efficiency of your room treatment. As they say, work smarter, not harder!









