Acoustics and Low Frequency Damping pt. 6

This week we conclude the discussion of an innovative method of designing room acoustics to optimize the low frequency performance. This method differs from traditional the architectural acoustics approach, and works much better for “small rooms” – such as the one in which you do your critical listening. From the AES paper titled as above, by ASC Owner & President, Art Noxon, comes the final excerpt from this enlightening piece.

View the entire paper.

How Many Traps?

The efficiency term () is defined as the ratio of energy absorbed to the energy presented. The ¼ wavelength pressure zone contains a discrete quantity of energy in a definable volume. The trap occupies part of that quadrant with its own volume (). 80% of the zone’s energy lies within 1/6 wavelength radius from the corner. The ratio of PZT volume to the 1/8 spherical section volume comprises the geometric efficiency (E). This is further reduced by the mechanical efficiency of the trap () itself; typically 50%.

The RT60 equation can be fitted with this efficiency term. Additional substitutions and reductions provide the RT60 to have an inverse frequency dependency. Recall the Sabine equations to not be directly frequency dependent.

There appears the dimensionless ratio in wave number space of the modal volume to the cubed modal length. This ratio is largest for symmetric modes (1, 1, 7) or (2, 2, 2) and smallest for the eccentric modes as (1, 2, 6). It is always less than unity and a mean value of 1/3 is chosen.

The use of traps sufficient to remedy a room’s poor low end ranges from one trap per 500 cubic feet to one trap per 250 cubic feet of room volume. This simplifies further the RT60 equation. The trap volume can be resolved for the 500 cubic foot ratio to be inversely dependent on both RT60 and frequency.

The typical acoustic efficiency is 50% for these three commercial traps. Their volume levels cross extended through the frequency range call out the RT60 vs. frequency plot for the 250 cubic foot or 500 cubic foot rate. For example, a 4 cubic foot trap provides 2 seconds at 20 Hz, 1 second at 50 Hz and ½ second at 90 Hz RT60 times.

Conversely, for a particular resonant frequency, room volume and required RT60, the number (J) of trapped volumes can be calculated.


Example

A room of 2,000 cubic feet needs an RT60 of 1/2 second at 50 Hz and tubes having a volume of 4 cubic feet each will be used. A total of 7 traps must be placed in the pressure zones of that mode resonance.

By utilizing PZT methods, an absorptive treatment for low frequency resonance can be specified. The () change in room Q is easily approximated.

The volume (Vt) of traps required to produce that change can also be defined.


Example

The 2,000 cubic foot room needed a Q adjustment of 50. The volume of PZT adjustment is 12 cubic feet.

The listening room is the last link in the audio chain. It is an acoustic coupler loaded with resonances. Hundreds of rooms have been developed into satisfactory listening environments by using the 500 cubic feet per trap rule. The average trap volume is 2.5 cubic feet. A correction in Quality of 60 is what the average acoustic treatment produces. Serious listening rooms usually require a correction in Quality of 30. This means the average (Q=40) listening room must have its Q cut in half and a serious room must have a Q equal to 1/3 its untreated Q.

A frequently asked question involves the number of traps required to reduce an existing RT60. PZT allows the answer without resorting to Sabine formulas.


Examples

A 2000 cubic foot room has an RT60 of 1.3 sec. at 50 Hz. We wish to reduce it to 0.7 sec. using 4 cubic foot traps. Calculations show 4.4 traps will lower the RT60 as required.

A 2000 cubic foot soft room with an RT60 of 0.5 seconds needs to be reduced to 0.3 seconds. Using 4 cubic foot traps, calculations show 9 are needed.

If RT60 equipment is not available, a slow sine sweep frequency response will suffice. Measure the 3 dB down bandwidth . Substitute its relation for initial RT60. The desired RT60 is often specified and doesn’t need conversion to final bandwidth.


Reverb Chamber

Absorption is usually measured in reverb chambers using RT60 values and the Sabine absorption formula. PZT equations can be rearranged into the same format. The distinctive frequency dependence of PZT absorption is clear. This relation connects standard Sabine lab methods to PZT theory.


Conclusion

A listening room does not have an acoustically flat response. Most rooms can play better when their Q is reduced by a factor of 2 or 3. Room color is damped out from the listening ambience. It is the Q not the EQ that distinguishes the listening room from a standard room. Pink noise is an appropriate test signal for EQ settings. Pure tone, not 1/3 octave sweeps or RT60 are required to monitor the room Q.

The Pressure Zone Trap (PZT) approach provides a rational view of discrete absorptive devices in the resonant field. It allows specifications to reduce the RT60, or Q of the room to acceptable.


There you have it. Reduce the “Q” of your room’s resonances to a sufficiently low level, and your listening experience will be elevated to new levels.

Use the formulas above to determine how many TubeTraps you should add to achieve this reduction in Q. Then give us a call and we’ll take care of the rest.

We hope you’ve enjoyed this series.