One-Dimensional Resonance Decay, Continued.The single trap at the end of the tube has access to one-half the total energy in the tube. There are two pressure zones, ¼ wavelength in size for the first harmonic. 
The second harmonic has its energy split amongst four ¼ wavelength zones. The trap has access to only ¼ the total energy stored in the resonant condition. 
The third harmonic has six discrete pressure zones. The trap only works 1/6 of the total energy in the field. The relative size of the trap to the zone increases with higher mode (j) numbers, so its efficiency increases. 
Multiple traps in a resonant field increase the fraction of energy removed each pressure pulse. Two properly placed traps in the third mode or harmonic has access to 2/6 or 1/3 of the system’s energy. 
The total number of ¼ wavelength pressure zones is twice the mode number. The fraction of energy lost per pressure pulse is the ratio of trapped zones (J) to the total number of zones (2L) times an efficiency term. (η) 
The RT60 equation can be written for one dimension trapping. For small absorption, the approximation is made. 
The simple Sabine decay formula for one dimension is a classic derivation. A pulse is injected into the impedance tube. Absorption is located at the tube end. The fraction of energy lost upon impact is the absorption coefficient ( ) 
The PZT decay formula can be converted into a form like the Sabine. Any frequency of resonance belongs to one of a harmonic series. It is the multiple of the mode number (L) and fundamental frequency (fo). Since absorption is only at one end of the tube for both cases, only one pressure zone is trapped. 
The efficiency term (η) in PZT analysis and the absorption coefficient ( ) in Sabine calculations have the same physical definition. It is the ratio of energy lost to initial energy. For the one dimension systems, PZT rationale results in the same conclusion as does the classic Sabine analysis. 
Two Dimensional Decay RatesThe two dimensional physical space is outlined by an X and Y dimension. Each resonant mode is identified by a “mode number,” a set of two whole numbers (L,M). If one of the mode numbers is zero, the one dimensional model develops. 
The standard equation for the frequency of a resonant mode has two components. They can be converted into wave numbers by dividing each mode number by its associated physical length. The mode frequency equation can be rewritten in terms of wave numbers. 
The primitive cell in two dimensions is the (1,1) mode. Positive pressure in opposite corners with negative pressure in the other two marks the energy distribution at one moment. A half cycle later the polarity reverses. Between these moments are complimentary patterns of kinetic energy distribution. 
There are a total of 4 quarter wavelength zones in the pressure distribution of the primitive cell. They are in the corners. All the energy in the resonant cell is found within these four zones twice each cycle. 80% of a zone is found contained within the radius, 1/6 of the wavelength from the corner. 
Higher mode numbers are simply more such cells packed into the same space. A (2,1) mode has two cells in the X axis and one cell in the Y. A (2,2) mode is two cells wide by two cells high. The total number of cells is the product of the two mode numbers. 
The total number of pressure zones (K) will be four times the number of cells in a mode. If some number (J) of them are absorptively trapped, the fraction of pressure zones trapped is known if the efficiency term is included. 
The RT60 formula derived for PZT methods is general and can be applied to this two dimensional case. For light absorption, a further simplification results. 
|